The minimum roof slope allowed by code for any type of roof is in 12 applicable only to coal tar pitch roof systems.
Minimum flat roof slope ibc.
It is very difficult to achieve in practice.
However this is only possible in theory.
Mineral surfaced roll roofing requires a minimum roof pitch of 1 12 or greater.
Asce 7 10 2015 ibc attributes ponding water to the deflection of relative flat roofs and identifies a susceptible bay for ponding as a roof slope less than 1 4 in 12.
For standing seam metal roof panel systems a 1 4 12 minimum roof slope is prescribed.
All roofs should be provided with a secondary drainage system to prevent water accumulation on the roof.
For water to flow on a flat roof the minimum slope must only be greater than 1 0.
Built up roofs require a minimum roof pitch of 1 4 12 or greater.
Some of the factors include.
Slate and slate type shingles require a minimum roof pitch of 4 12 or greater.
Asce 7 10 further clarifies roof surfaces with a slope of at least 1 4 inch per foot 1 19ยบ towards points of free drainage need not be considered a susceptible bay.
This is the basis for calculating the angle which is approximately a 1 19 degree slope.
This 1 4 12 minimum roof slope requirement also applies to spray polyurethane foam spf roof systems in new construction.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
All roofs should have primary drainage designed to the requirements of the ibc and the plumbing code.
Due to this there are other factors that are taken into account when working out the ideal slope for a flat roof.
Wood shakes require a minimum roof pitch of 3 12 or greater.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Wood shingles require a minimum roof pitch of 3 12 or greater.
Apply a minimum 19 inch wide 483 mm strip of underlayment felt parallel with and starting at the eaves fastened sufficiently to hold in place.
When required testing is in accordance with astm e108 or ul 790.
For roof slopes from two units vertical in 12 units horizontal 17 percent slope and up to four units vertical in 12 units horizontal 33 percent slope underlayment shall be two layers applied in the following manner.
Minimum roof fire resistance ratings apply based on the type of construction and some building types do not require a fire rating.
It is the opinion of rci that the lack of such provisions in the 2015 ibc will increase the probability of roof collapses.
The ibc table 1505 1 lists the minimum requirements for roof covering fire resistance classifications a b or c for all types of.