Tpo s long term heat uv and natural fungal resistance plus flexibility without need for plasticizers also make tpo a reliable low slope roofing system.
Minimum slope for single ply membrane roofing.
Astm d4637 standard specification for epdm sheet used in single ply roof membrane.
Apply a single ply adhesive that will adhere to the existing membrane as a primer thick enough to accept a full broadcast of 16 grit silica sand or granules.
For example the international building code 2018 edition ibc 2018 prescribes a 1 4 12 minimum roof slope for asphalt built up polymer modified bitumen thermoset and thermoplastic single ply and liquid applied membranes in new construction.
These membranes are particularly effective for roofs with a very low slope between 1 8 12 1 and 4 12 33.
Higher density products provide improved impact resistance.
The use of the resisto self adhered waterproofing membrane as a first layer and the resisto granulated cap sheet high resistance hr cap sheet as a second layer is an ideal solution to ensure the waterproofing of low slope roofs.
The resisto single ply roofing system is guaranteed for 15 years against any manufacturing defect that may cause leaks.
The slope of the roof must not be less than 1 12 8.
This means for every 12 horizontal units the roof must rise a minimum of one fourth vertical unit.
Single ply membrane has a weft insertion anti wicking scrim with a density of 18 by 14 threads per inch among the highest in the industry.
This warranty applies to low slope roofs that use the outer perimeter instead of a drain to evacuate water.
Sprayed polyurethane foam roofing.
The idea is to provide positive drainage toward roof drains so there is no ponding water 48 hours after a rain storm.
Thermoplastic single ply membrane roofs must have a design roof slope of 1 4 12 or greater 2 slope.
Unique in the industry duro last offers a 15 year warranty with consequential damage coverage for duro last prefabricated roofing systems with no additional charge.
Table 1 01 1 chart of roofing system applicability thermoplastic single ply membranes back nailing table 1 03 1 back nailing requirement for sloped roofs table 1 04 1 the minimum fastener pullout resistances for specific systems.
Thermoplastic single ply roofing minimum roof slope roof pitch r905 13 1.
A minimum slope of 0 25 inches per foot 2 percent is recommended for all low slope roofing systems for adhered systems the substrate must be one that is approved by the system supplier.
Short for thermoplastic polyolefin tpo is a single ply roofing membrane that offers excellent performance at a cost effective price.
Roofing membranes that are single ply such as a pvc tpo or epdm requires a thin layer of a compatible single ply adhesive to be used as a primer for roofslope.